Build a Reliable Calibration Laboratory Faster

Building your own in-house calibration laboratory is not just about purchasing equipment. You also need to use the correct technique, lab design, procedures, documentation management, and calibration practice.

Our customized training service will help you develop or enhance your calibration laboratory for pyranometers and reference cells calibration. The service is flexible and can be adapted for indoor, outdoor, or both calibration types.

Training can be provided either at the ArGesim factory in Türkiye or at the customer premises.

What the Service Includes

Pyranometer Calibration

Depending on your needs, the training may cover:

  • Calibration principles and practical methods
  • Indoor and outdoor calibration workflows
  • Laboratory layout planning
  • Equipment selection & supply
  • Traceability and documentation
  • Data collection and certificate preparation
  • Good practices for repeatable results
  • Guidance for daily laboratory operation

Provided Materials & Services:

The service can include the following materials, equipment, software, and technical support depending on the selected laboratory configuration:

The Provided Material for Indoor Calibration Setup

Category Provided Material / Service Notes
Reference Equipment Calibrated reference sensor from ISO/IEC 17025 laboratory Optional; can be purchased by customer
Light Source Class AAA sun simulator according to IEC 60904-9 Provided by BallastCo
Mechanical System Sensor delivery mechanism Provided by BallastCo
Data Acquisition Datalogger Optional; can be purchased by customer
Software for data acquisition Provided by BallastCo
Software Calibration software and certificate creation/printing software Designed according to ISO/IEC 17025 documentation needs
Training & Know-How 3-day theoretical and hands-on training Provided by BallastCo
Application Coverage Pyranometer and irradiance/reference sensor calibration Scope can be customized

The Provided Material for Indoor Calibration Setup

Category Provided Material / Service Notes
Reference Equipment Calibrated reference sensor from ISO/IEC 17025 laboratory Optional; can be purchased by customer
Mechanical System Customized sensor calibration stand Provided by BallastCo
Data Acquisition Datalogger Optional; can be purchased by customer
Software for data acquisition Provided by BallastCo
Software Calibration software and certificate creation/printing software Designed according to ISO/IEC 17025 documentation needs
Training & Know-How 3-day theoretical and hands-on training Provided by BallastCo
Application Coverage Pyranometer and irradiance/reference sensor calibration Scope can be customized

International Standards Used

The training course utilizes the following internationally recognized standards:

  • ISO 9847:2023 for pyranometer calibration
  • IEC 60904-2:2023 for photovoltaic reference devices
  • IEC 60904-4:2019 for reference solar devices
  • IEC 60904-9:2020 for solar simulator classification
  • ISO/IEC 17025:2017 for laboratory competence, traceability, and documentation

Options for Indoor and Outdoor Calibration

The program can be set up for:

Indoor calibration using equipment like the sun simulator, sensor delivery device, datalogger, software, certificate generator, etc.

Calibration Laboratory

Outdoor calibration using custom-made mounting systems along with natural sunlight-based calibration procedure.

Calibration of Pyranometer

The final configuration is determined based on your application, space availability, technical goals, and preferred calibration approach.

BallastCo Lab. Equipment for the Program

BallastCo Lab. Equipment will provide all major equipment needed to establish a calibration laboratory, such as:

  • Sun simulator
  • Sensor delivery device
  • Datalogger along with its software
  • Software for certificate preparation
  • Custom-made mounting systems for the sensors

The sensor delivery device can be customized for either pyranometer or reference cell calibration.

SEVEN can additionally offer optional third-party services for calibration of reference sensors upon request from clients.

Training Location

The training can take place:

  • In the ArGesim production facility in Türkiye
  • In the facilities of the customer

On-site training may be particularly effective when customization of the program is required for the client’s particular conditions.

Calibration of Reference Cell

Build Your Own Calibration Laboratory

Each calibration laboratory requires unique specifications. This explains why our services are completely tailored to individual needs.

We offer you calibration laboratory design solutions for your pyranometer or reference cell and provide you with a customized quote.

Contact us to plan your calibration laboratory training.

Frequently Asked Questions FAQ about Turnkey Calibration Laboratory Setup

What is a pyranometer and reference cell calibration laboratory?

A calibration laboratory is a facility which can calibrate solar irradiance measurement sensors with reproducible accuracy.

What equipment is required for a calibration laboratory?

Equipment such as a reference sensor, sun simulator, mounting, datalogging, calibration software and certificate generator is typical of a calibration lab.

Can we make our own calibration laboratory?

Yes. We can guide companies with the planning and equipping of their own pyranometer and reference cell calibration laboratory.

Is this a pure training service?

Not always. It can also include other services like equipment selection and supply, setup of the lab and workflow, document preparation.

Is the calibration performed in indoor and outdoor conditions?

Yes. Indoor calibration uses artificial light sources such as the sun simulator while outdoor calibration uses sunlight and its own mounting setup.

Which international standards apply?

This service is compliant with ISO 9847, IEC 60904-2, IEC 60904-4, IEC 60904-9 and ISO/IEC 17025 requirements.

Do you prepare our laboratory for ISO/IEC 17025?

Yes. Preparation of calibration and traceability process documentation and certificate is among the possible tasks of this service.

Is it possible to utilize my laboratory equipment?

Of course, if your equipment satisfies technical requirements for a calibration laboratory.

Where can training take place?

Training can be performed in the ArGesim premises in Türkiye or at the customer’s premises or laboratory.

How can we begin the calibration lab project?

We can begin with you informing us about your application, calibration scope, equipment, and whether indoor/outdoor setting is preferred.